Rat Cardiotrophin-1 (CT-1) ELISA Kit

Rat Cardiotrophin-1 (CT-1) ELISA Kit

(Used in serum, plasma, cell culture supernatant and other biological fluids)

principle

This experiment uses the double antibody sandwich ABC-ELISA method. Coated with anti-rat CT-1 (Cardiotrophin-1) monoclonal antibody on the microtiter plate, CT-1 in the standard and the sample is combined with the monoclonal antibody, and biotinylated anti-rat CT-1 is added to form an immunity The complex is connected to the board, and the horseradish peroxidase-labeled Streptavidin is combined with biotin. The substrate working solution is added and the blue color is added. Finally, the stop solution sulfuric acid is added. The OD value is measured at 450nm, and the CT-1 concentration and OD value are measured. It is proportional to the CT-1 concentration in the specimen by drawing a standard curve.

Kit composition (stored at 2-8 ° C)

Coated Wells

96 wells

Enzyme Conjugate

12ml

10 × Sample Buffer

12ml

20 × concentrated washing solution (Wash Buffer)

50ml

Standards (Standards): 1ng / bottle

2 bottles

Substrate working solution (TMB Solution)

12ml

The first antibody working solution (Biotinylated Antibody)

12ml

Stop Solution (Stop Solution)

12ml

Prepare reagents and collect blood samples

1. Collect specimens: serum, plasma (EDTA anticoagulation), cell culture supernatant, tissue homogenate, etc., as soon as possible, stored at 2-8 ℃ for 48 hours; longer time must be frozen (-20 ℃ or -70 ℃) To avoid repeated freezing and thawing.

2. Standard solution preparation: add 0.5ml of distilled water to mix well before use to make a solution of 2000pg / ml. Set 8 standard tubes, and add 300ul of sample dilution to each tube. Add 300 ul of the standard solution of 2000 pg / ml to the first tube and mix it. Then aspirate 300 ul with the pipette and move to the second tube. Repeat the double dilution in this way, draw 300ul from the seventh tube and discard. The eighth tube is a blank control.

3. The 10 × specimen dilution is diluted 1:10 with distilled water (example: 1ml concentrated dilution + 9ml distilled water).

4. Washing solution: 1:20 dilution with redistilled water (example: 1ml concentrated washing solution is added with 19ml of redistilled water)

Testing procedures

1. Add sample: add 100ul of standard or sample to be tested to each well, mix the reaction plate thoroughly and place at 37 ℃ for 120 minutes.

2. Wash the plate: wash the reaction plate 4-6 times with the washing solution, and print it on the filter paper.

3. Add 100ul of the first antibody working solution to each well. The reaction plate was mixed thoroughly and then placed at 37 ° C for 60 minutes.

4. Wash board: same as above.

5. Add 100ul of enzyme-labeled antibody working solution to each well. Place the reaction plate at 37 ° C for 30 minutes.

6. Wash board: same as above.

7. Add 100ul of substrate working solution to each well, and place in a dark place at 37 ℃ for 15 minutes.

8. Add 100ul of stop solution to each well and mix well.

9. Measure absorbance at 450nm with a microplate reader within 30 minutes.

Result calculation and judgment

1. All OD values ​​should be calculated after subtracting the blank value.

2. With the standard products 1000, 500, 250, 125, 62.5, 31.2, 15.6, 0 pg / ml as the abscissa, and the OD value as the ordinate, draw a graph on the graph paper and draw a standard curve.

3. Find the corresponding CT-1 content on the graph according to the OD value of the sample.

Kit performance

1. Sensitivity: The smallest CT-1 detection concentration is less than 10pg / ml.

2. Specificity: simultaneous detection of recombinant or natural rat CT-1. Does not cross-react with other cytokines in rats.

3. Repeatability: The coefficient of variation within the board and the board is less than 12%.

Precautions

1. The above standard holes and samples to be tested are recommended to be re-holes, and the standard curve should be made at the same time for each measurement.

2. The washing process is critical. Insufficient washing will lead to an increase in accuracy error and OD value.

3. After opening the slats, the remaining slats should be sealed again to keep the slats dry.

4. This kit should be stored in a 4oC refrigerator.

5. This kit is for scientific research only, not for clinical diagnosis!

Home Office Computer Table

Home and Office Table series are big series and multipurpose that it includes Side Table, Laptop Table, Computer Table and so on.Those can be used for Office and Home.Material also can be wood, MDF, steel frame and so on different on different customer`s requirement.

HEALTH AND WELLNESS: Standing Desk encourages greater movement throughout your day while helping optimize your cognition, improve focus, enhance collaboration, reduced back and neck pain, increase productivity and boost calorie burn.

Office Desk, Executive Desk, Standing Desk,Home Office Computer Table

Foshan Hollin Furniture Co.,Ltd , https://www.chnhollin.com

Posted on